Skip to content

An issue was discovered on Victure WR1200 devices through...

High severity Unreviewed Published Dec 1, 2021 to the GitHub Advisory Database • Updated Feb 1, 2023

Package

No package listedSuggest a package

Affected versions

Unknown

Patched versions

Unknown

Description

An issue was discovered on Victure WR1200 devices through 1.0.3. A command injection vulnerability was found within the web interface of the device, allowing an attacker with valid credentials to inject arbitrary shell commands to be executed by the device with root privileges. This occurs in the ping and traceroute features. An attacker would thus be able to use this vulnerability to open a reverse shell on the device with root privileges.

References

Published by the National Vulnerability Database Nov 30, 2021
Published to the GitHub Advisory Database Dec 1, 2021
Last updated Feb 1, 2023

Severity

High

EPSS score

1.859%
(89th percentile)

Weaknesses

CVE ID

CVE-2021-43283

GHSA ID

GHSA-mw64-2c3h-ccp9

Source code

No known source code

Dependabot alerts are not supported on this advisory because it does not have a package from a supported ecosystem with an affected and fixed version.

Learn more about GitHub language support

Loading Checking history
See something to contribute? Suggest improvements for this vulnerability.